Palmer Municipal Fire Department

Donate Now

Training Association

2026 Runs
JAN  62
FEB  80
MAR  74
APR  78
MAY  76
JUN  95
JUL  95
AUG  76
SEP  74
OCT 
NOV 
DEC 
Total 710

Past Incidents
2025 840
2024 971
2023 825
2022 736
2021 752
2020 705
2019 744
2018 766
2017 790
2016 708
2015 641

Web Counters
Website Visitors
Since
December 1, 2014
1,828,521
Visitors Today
Oct 28, 2026
882

Smoke Detectors - Letter from the Fire Commissioner

Print RSS Facebook Twitter RSS

By PMFD Web Administrator
March 5, 2015

How old are the smoke detectors in your house, place of business? Did you know that smoke detectors ten years old or more should be replaced? Palmer Municipal Fire Department has seen a rise in faulty smoke detectors the past few months. No fires, injuries, or loss of property have resulted in these faulty smoke detectors.

The National Fire Protection Association (NFPA) indicates that smoke detectors, after ten years old, need to be replaced. Most manufactures stamp this warning on the back of the smoke detector along with the manufacture date of that particular detector. Replacement smoke detectors may be purchased at any home improvement store.

There are two types of smoke detectors; Ionized and Photoelectric. Each provides a certain level of protection. An Ionized smoke detector responds quicker to a flaming fire while Photoelectric smoke detectors respond quicker to smoldering fires.

Ionized Smoke Detectors use electrodes connected to two metal plates and a battery to complete a circuit. When smoke enters the smoke detector chamber, ions from the completed circuit bond to the smoke causing the break in the circuit and activation of the smoke detector.

Photoelectric Smoke Detectors respond quicker to a fire condition than Ionized Smoke Detectors. In Photoelectric smoke detectors are two chambers. One chamber is an LED light similar to a laser pointer that send a straight beam of light from one side of the chamber to the other. At the bottom of the chamber with this beam of light is another chamber with a light sensor that detects the beam. As smoke enters the two chambers, the LED beam is interrupted causing the light sensor to activate the smoke detector.

Smoke detectors should be located on each level of your residence as well as inside each bedroom. Detectors should be mounted on the ceiling but may be mounted on the wall. If mounted on the wall, detectors should be located between 4 and 12 inches from the ceiling. Any detectors mounted on the ceiling should not be mounted closer than 4 inches to any wall and not mounted under ceiling fans or other types of hanging obstructions. If mounting smoke detectors in or near a Kitchen, this detector should be mounted a minimum of 10 feet from the stove.

For additional information on smoke detectors and other fire warning devices please visit the NFPA website at http://www.nfpa.org/safety-information

Also visit our Fire Prevention section for additional information.


Add a Comment Add a Comment 0 Comment(s)


Website Designed and Hosted By: Content Proudly Maintained By: Contact Info:
Firehouse Solutions
www.FirehouseSolutions.com
Palmer Municipal Fire Department
3 Weller Place
Palmer, PA 18045
Emergency Dial 911
Non-Emergency: 610-559-9809
E-mail: info@palmerfire.org
Copyright © 2026 Firehouse Solutions (A Service of Technology Reflections, Inc.)